Industrial Internet of Things
Sensors are paramount to industrial processes that are increasingly automated and digitally networked since processes are impossible to control without the reliable acquisition of signals and measurement data. The chapter “digital base” is old hat already at BD|SENSORS, many variations of pressure and fill level acquisition are currently communicating with the digital periphery.
Measuring technology 4.0 – reality already at BD|SENSORS
MEASUREMENT TECHNOLOGY FOR INDUSTRY 4.0
DCL 531i
stainless steel sensor
with RS485 Modbus RTU Ø 26,5
- nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O
- accuracy:0,1 % FSO
DCT 531i
pressure sensor: stainless steel
mit RS485 Modbus RTU
- nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
- accuracy:0.1 % FSO
DCT 531
pressure sensor: stainless steel
with RS485 Modbus RTU
- nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
- accuracy:0.25% FSO
DCT 532
pressure sensor: stainless steel
with i²C interface
- nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
- accuracy:0,25 % FSO
DCT 533
pressure sensor: stainless steel
with IO-Link interface
- nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
- accuracy:0.35 % (opt. 0.25%) FSO
DCT 531P
pressure sensor: stainless steel
with RS485 Modbus RTU
- nominal pressure:0 ... 100 mbar up to 0 ... 40 bar
- accuracy:0,25 % FSO
DCT 533P
pressure sensor: st. steel (strain gauge)
with IO-Link interface
- nominal pressure:from 0 ... 100 mbar up to 0 ... 40 bar
- accuracy:35 % (Opt. 0,25%) FSO
DCT 553P
pressure sensor: ceramic
with IO-Link interface
- nominal pressure:from 0 ... 40 mbar up to 0 ... 20 bar
- accuracy:0.35% (opt. 0.25%) FSO
DCT 571
pressure sensor: ceramic
with RS485 Modbus RTU
- nominal pressure:from 0 ... 100 mbar up to 0 ... 60 bar
- accuracy:0,35% (opt. 0,25%) FSO
DCL 531
stainless steel sensor
with RS485 Modbus RTU
- nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O
- accuracy:0,25 % FSO
DCL 532
stainless steel sensor
with I2C
- nominal pressure:from 0 ... 1 mH2O up to 0 ... 40 mH2O
- accuracy:0,25 % (Opt. 0,1 %) FSO
DCL 571
ceramic sensor
with RS485 Modbus RTU
- nominal pressure:0 ... 1 mH2O up to 0 ... 100 mH2O
- accuracy:0.35% (opt. 0.35 %) FSO
DS 350
stainless steel sensor
with IO-Link interface
- nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
- accuracy:0.5% / 0.35 % (opt. 0.25 %) FSO
DS 351
ceramic sensor
with IO-Link interface
- nominal pressure:0 ... 0,4 bar bis 0 ... 600 bar relativ, 0 ... 0,6 bar bis 0 ... 600 bar absolut
- accuracy:0,5 % FSO
DS 350P
stainless steel sensor (flush)
Food industry, Pharmacy
- nominal pressure:from 0 ... 100 mbar up to 0 ... 40 bar
- accuracy:0.5% / 0.35 % (opt. 0.25 %) FSO